All dimensions are shown in millimetres (mm), all pressures/ forces in Newtons (N / F1) and all temperatures are in degrees Celsius (C°).
The devices MUST be mounted with the rod downwards (with a minimum incline of 15°);
for horizontal installation or with rod-upwards, please contact us.
Protect the rod against impacts, electric arc flashes, grinding sparks, paint and corrosive products. Do not tighten the rods with pliers or in a clamp without using protective lead, aluminum or copper grips.
Number of cycle / minute : maximum 5. For a higher rate, please contact us.
For a maximum storage time of three months, the devices may be stored horizontally, in an ambient temperature.
For a longer storage time, or in a hot country, store them vertically, with the rod down.
1 year starting form the date marked on the device. Example of date marking: 1011 (10th week of 2011).
For the warranty to remain, if the device is to be repainted the manufacturing date must remain visible.
Gas springs hold an inside pressure up to 160 bar, it's necessary to release the gas before disposal. For your safety, please respect the following procedure:
To carry this out:
It is essential to wear safety glasses.
Use a metal handsaw
Place a cloth over the blade.
As soon as a whistling sound is heard, stop sawing.
The gas removal will be complete when the rod can easily be moved by hand.
Force in Newtons | Margin tolerance |
---|---|
30 ≤ N < 50 | + or - 10 N |
50 ≤ N < 250 | + or - 20 N |
250 ≤ N < 750 | + or - 30 N |
750 ≤ N < 1500 | + or - 60 N |
1500 ≤ N < 3000 | + or - 150 N |
3000 ≤ N < 6000 | + or - 300 N |